Where the mist is decides everything. If it is between the panes and will not wipe off, the sealed unit has failed and the pane is replaced. If it wipes off the room side, it is surface condensation and the window is fine. If it is on the outside face on a clear morning, it is dew and it means the glass is performing well.
The ten second test
Wipe it.
Mist that clears with a cloth is on a surface. Mist that stays when both faces are dry is inside the sealed unit, and no amount of ventilation will change it.
That single check separates a fault from a habit.
What a failed sealed unit is
The mechanism, and how the edge seal fails, is on why is my rooflight misted up.
What follows here is the repair route for a branded roof window, which is better than it is for most products.
Why the pane rather than the window
Because the failure is in one component.
A frame, a sash, the flashing and the reveal are all unaffected by a failed edge seal, so replacing the whole window replaces a great deal that is still doing its job.
What the plate tells you
Whether a pane is available.
The type designation, the size code and the year identify the sealed unit exactly, and whether that part is still supplied depends on the range and its age.
Finding it is on how do I find my VELUX size code.
How a pane is changed
On the sash, and generally from inside.
The sash comes out of the frame, the glazing beads or the retaining trim are removed, the failed unit comes out and the new one goes in with new seals.
No covering is lifted, which is why it is a modest job.
A whole sash instead
Sometimes the better value.
Where a sash is also tired, a complete replacement sash for the code arrives glazed and drops into the existing frame, which is one visit and a window that feels new.

Whether it is worth it on a very old unit
The comparison worth making.
A new pane in a forty year old sash gives you clear glass at the thermal performance of the era, where a new window would be a substantial step.
The difference is on will a new rooflight be warmer.
Where the range is no longer supported
The point at which replacement wins.
If no pane is made for the code, the choice is a like for like window into the same opening, which is a short job because the opening exists.
That route is on can a VELUX be replaced like for like.
Condensation on the room side instead
Far more common than a failed unit, and not a fault.
Warm moist air meets the coldest surface in the room and gives up its water there, and in a bedroom or a bathroom the glass is that surface.
What to do about it is on how do I stop condensation on a rooflight.
Why it is worse on a roof window
Because warm air rises to it.
The moisture in a room collects at the highest point, which in a loft bedroom is exactly where the glass is, so a roof window sees it before a wall window does.
Dew on the outside face
Counter intuitive and entirely good news.
A well insulated unit lets so little heat through that the outer pane cools to the temperature of the night sky, and dew forms on it exactly as it does on a car.
It clears within an hour of the sun reaching it.
Mist that appears only in one corner
Usually the seal rather than the glass.
A sash gasket that has taken a set lets a draught through at one point, and condensation collects there before it does anywhere else.
A new gasket is a stocked part.

Water sitting at the sill
The thing to deal with before it becomes rot.
The frame carries drainage channels that take condensation away, and when they clog with dust the water sits against the timber.
Clearing them is a two minute job with a cloth.
The ventilation flap
Frequently the whole answer in a bedroom.
A trickle vent in the head of the sash with a clogged filter behind it stops doing anything, and a bedroom with the vent shut all winter will mist every morning.
It rinses under a tap.
Whether a blind is making it worse
It can, marginally.
A tightly closed blind reduces the air movement over the glass, so moisture that reaches it lingers, and a blind left down all day in a cold room does not help.
How quickly a failed unit gets worse
Slowly, and then all at once in the wrong season.
A unit that mists faintly on cold mornings in the first year will mist most days by the third, and once mineral deposits have dried onto the inner faces the marks stay even when the mist clears.
There is no urgency about it beyond appearance, but it does not recover.
What it does to performance
Less than people fear, and it is not nothing.
The cavity gas has gone, so the unit performs closer to plain double glazing than to the figure it was sold at, which shows as a slightly colder pane rather than as a draught.
Whether it can be drilled and dried
The service that gets advertised, and we would not.
Drilling a unit to vent and dry it clears the appearance for a while, but the cavity is then open to the air permanently and the unit is no longer sealed.
On a roof, where the pane is doing thermal work, replacing the unit is the honest answer.
What we want to know on a VELUX
We ask for a photograph and the wipe test before quoting anything, because the difference between a failed pane and a bedroom that needs its vent opening is the difference between a job and a conversation.
The rest is on the VELUX window installation page.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.