The sizes fitted most often are the mid width codes, because they are the ones that fit between rafters or trusses at standard centres without any structural work. Within that width, the taller codes are chosen where a room needs the light or an escape opening, and the shorter ones where a purlin or a ceiling line limits how far the opening can run down the slope.
Why one width dominates
Because the roof chooses it rather than the customer.
A trussed roof gives a clear space between members, and after allowing for the frame and its fixings the practical width is fixed. Every house on a post war estate offers roughly the same figure.
So the same width codes go into thousands of similar roofs, and the height is where the variation is.
What the letter and the number mean
The letter is the width, the digits are the height.
Within one letter group every code shares a width and differs only in how far the window runs up and down the slope, which is exactly the freedom a trussed roof allows.
How to read yours is on how do I find my VELUX size code.
The escape sizes
A separate group, and they turn up in every loft conversion.
Where a loft room is a bedroom, one window has to provide a compliant clear opening, and that narrows the choice to particular codes in particular actions.
The requirement is on can a VELUX be an escape window.
The small sizes
Used more than people expect.
Landings, bathrooms, box rooms and stairwells rarely need a large window, and a small code in the right position does more for a dark landing than a large one badly placed.
They also suit a roof where the available slope is short.
The wide codes
Where structural work enters the conversation.
The wider codes span more than one bay on a standard roof, so they need a rafter trimmed and the load carried into its neighbours, which is a designed alteration rather than a fitting decision.
On a trussed roof it is a larger step again.

Two windows instead of one wide one
The answer most rooms end up with.
Two mid width units in adjacent bays give more glass than one wide one, light the room from two directions and need no structural work at all.
Where they should sit is on how far apart should two roof windows be.
What decides the height
Three things, and usually the roof rather than the room.
The purlin on an older cut roof, the flat ceiling line inside a loft room, and the clearance needed above the eaves all limit how far an opening can extend down the slope.
The available height is measured inside before a code is chosen.
The sill height for escape
The one measurement that overrides the others.
An escape window has to have its sill within reach of the finished floor, which on a chalet bungalow or a room with a knee wall can rule out a taller code sitting higher up the slope.
What turns up on inter war Worthing stock
Cut roofs with purlins, and the height limited by them.
Semi detached houses of the twenties and thirties across Worthing have purlins running through the loft, so the openings sit either above or below them and the codes reflect that.
What that means locally is on Broadwater.
What turns up on post war estates
Trussed roofs and consistent widths. Estate housing from the sixties onward is trussed throughout, so the width is fixed and every job on the street uses the same handful of codes.
The constraint is on can a roof window be fitted between trusses.

What turns up on a village roof
Smaller units, chosen for appearance. On a historic slope the size is often decided by what looks right in the covering rather than by what the room would like, and small codes read far better on a hand made clay roof.
Why a common size is easier to buy
Availability and price both. Popular codes are stocked, so the window, the flashing kit and the blinds are all readily available, where an unusual code can mean a lead time on every one of those.
It is worth knowing when a programme is tight.
Why a common size is easier to live with
Because the accessories exist. Blackout blinds, awnings, insect screens and control rods are all made against the code, and the range available for a popular size is wider than for an unusual one.
Matching an existing window
Worth doing where two are on the same slope.
A second window in a matching code, set out from the same course, reads as a pair. One a size larger reads as an afterthought from the garden.
Where the room should override the roof
Occasionally, and it is a real decision.
Where a room genuinely needs more light than the standard width allows, the structural work to widen an opening is a legitimate choice rather than something to be avoided on principle.
It is priced and decided rather than assumed away.
What we measure on a VELUX
We measure the actual centres and the available height on the roof in question before naming a code, because a size that is common nationally may not be the one this particular roof wants.
The rest is on the VELUX window installation page.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.