There are two good answers and one poor one. Either the windows sit close together with a combination flashing kit made for the gap, or they sit well apart with full courses of covering running between them. The spacing in between, a few hundred millimetres of awkward cut tiles, is the one that causes trouble and the one to design out.
Why the middle distance fails
Because the covering cannot do its job in it.
Tiles and slates need enough width to lap and to be nailed or clipped, and a narrow strip between two flashings ends up as slivers held on mortar or nothing at all.
It is the detail that lifts in a gale.
What a combination kit does
Weathers the pair as one opening. Manufacturers make flashing kits for windows set at a fixed narrow spacing, generally around a hundred millimetres, with a formed gutter between them that takes the water away properly.
The kit only works at the spacing it is made for, which is why the frames are set out to it.
Side by side against one above the other
Different kits and different reasons. Side by side widens the light and suits a room lit across its width. One above the other, up the slope, suits a tall room or a stairwell and needs a kit with a vertical gutter and a bridging flashing.
The vertical arrangement is more demanding of the covering.
What sets the spacing when they are apart
The rafters, not the room. On a trussed roof each window occupies a bay, so the spacing is a whole number of bays and the practical minimum is one bay apart with a rafter between.
The measurement is taken on site, as on can a roof window be fitted between trusses.
Two bays rather than one
Often the better look. With one truss between them the windows read as a pair with a stripe of tiles down the middle. With two, they read as two windows, evenly placed on the elevation.
Which is right depends on the wall below more than on the roof.

Lining up with what is below
The thing that makes an elevation look considered.
Roof windows centred over the windows below, or symmetrically about a door, look intended. Windows placed only for internal convenience often do not.
It costs nothing to check at survey and it cannot be changed afterwards.
Light in the room
Where spread beats concentration. Two windows apart light a room far more evenly than two together, because each throws its own patch and the shadows between furniture are filled from two directions.
Two together give one bright area and a bright wall.
When together is right anyway
Where the view or the wall dictates it.
A pair over a desk, over a bed, or framing a single view work as one aperture, and a combination kit is the correct way to build that.
It is a deliberate composition rather than a compromise.
Distance from the ridge and the eaves
The other spacing question, and it is fixed by the flashing.
A kit needs a run of covering above the window to lap under and a run below to lap over, so a window cannot sit hard against a ridge or an eaves course.
Manufacturers state a minimum, and it is generally a couple of courses either way.
Distance from a valley or a hip
Tighter than people expect. A valley concentrates water and a hip cuts the courses at an angle, so a window near either leaves cuts that are hard to weather.
Keeping clear of both is worth a repositioning.

Where a purlin lands
The constraint on a cut roof. A purlin runs across the rafters and a window cannot straddle it, so on an older roof the vertical position of both windows is set by where the purlin sits.
That frequently decides the arrangement before anything else does.
Matching heights
The detail people notice from the garden.
Two windows on the same slope at different heights up the roof look like an accident unless there is a visible reason, so they are set out from the same course wherever the structure allows.
Windows on two different slopes
A different question with more freedom. Front and back, or either side of a ridge, are not seen together, so they are positioned for the rooms rather than for each other.
Only a corner view sees both, which is worth a moment at survey.
The gap and the ceiling below
Sometimes the deciding factor.
Two reveals close together leave a narrow rib of ceiling between them, which can be elegant or can look like a mistake depending on how wide it is.
It is worth marking on the ceiling before the roof is opened.
Three or more on one slope
Where rhythm starts to matter more than spacing.
With three windows the eye reads the intervals rather than the units, so equal gaps look deliberate and one odd gap looks like a mistake, however sensible the reason inside.
Setting out from the centre of the slope rather than from one end is what keeps it even.
How we set it out on a pitched roof
We set out from the rafters and then check the elevation from the garden, because the spacing that suits the room and the spacing that suits the house are not always the same and both are decided before we cut.
The rest is on the roof window installation page.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.