Electric and Opening Rooflight Installation

Retrofitting an actuator to an existing unit, and when it is not possible

A manual rooflight that has become inconvenient to reach is a common problem, and the obvious answer is to add a motor to it. Sometimes that is straightforward. Frequently it is not, and the deciding factor is the window rather than the motor.

The question is whether the frame was designed for it

An actuator does not simply sit against a window. Its case is fixed to the frame and the free end of its chain is fixed to the sash, and both of those connections carry real force every time the window moves.

Manufacturers who offer a retrofit kit have designed those mounting points into the frame section from the start: defined positions, adequate material behind them, and a bracket made to fit. Where that provision exists, fitting a kit is a straightforward job.

Where it does not, there is nothing to bolt to except the visible face of a frame that was never intended to take the load, and no amount of ingenuity makes that a good idea.

Start with the data plate

The type code identifies the model family, and that is what tells you whether a kit exists.

It takes seconds, it is definitive, and it saves a considerable amount of speculation. Where the plate is missing, the frame profile and the ironmongery usually identify the generation well enough to check.

Where and how to find and read the plate is set out on the data plate page.

What has to be there already

The five conditions a retrofit needs
Condition Why If absent
A kit made for the model Mounting points designed into the frame No retrofit. This is the hard stop
A sound frame and sash The mountings carry cyclic load Replace the unit, not the mechanism
Free mechanism The motor has to move what is there Free it first, or the actuator fights it
Serviceable gaskets Hardened seals raise the closing load Replace them at the same time
A supply, or a solar option The motor needs power Solar, or accept the disruption

The four things that rule it out

Any one of these ends the conversation, and it is better to establish them at survey than after a kit has been bought.

  • No kit exists for the model. The commonest reason, and it applies to a great many older units.
  • The frame is at the end of its life. A retrofit into a unit that needs replacing in three years is money spent twice.
  • The action is wrong. Some actions do not accept powered operation in a way that is useful.
  • The unit is a size or generation no longer supported. No kit, no parts, and nothing to work with.
Marine grade stainless steel fixings and a coated aluminium frame section laid out on a roof membrane before installation, salt haze in the air
Where a retrofit is genuinely good

Where a retrofit is genuinely good

Two situations account for most of the successful ones.

A comparatively recent unit, in good condition, in a room whose use has changed: a boxroom that became a bedroom, or a loft that acquired an en suite. The window is fine and the reach requirement changed around it.

And a household where somebody who used to manage a pole no longer finds it easy. That is a foreseeable change and a retrofit is exactly the right response to it.

Power, and the reason solar exists

A retrofit almost by definition happens in a finished room, which means the cable route through the ceiling closed years ago.

That is precisely the situation solar powered actuators were made for. The unit carries its own panel and battery, so there is no supply to run, no plaster to chase and no boards to lift.

On a retrofit it is frequently not merely the easier option but the cheaper one once the disruption of getting a mains cable in is counted honestly.

What a retrofit does not fix

A motor makes a window easier to operate. It does not improve anything else about it.

The glass stays the glass it was, so a single glazed or early double glazed unit still performs as it did. A cold reveal stays cold, because that is the insulation collar rather than the mechanism. A leak stays a leak. And gaskets that were hard before are hard afterwards.

Which is worth weighing, because on a unit that is thirty years old the honest comparison is not motor against no motor. It is a retrofit against a replacement that brings the glass, the collars and the mechanism up to date together.

The arithmetic that decides it

Roughly, a retrofit is worth it where the unit has a decent proportion of its life left and its performance is acceptable.

Where the window is already misted, draughty, cold at the reveal or difficult to close, a motor is being added to a problem. The kit plus a service visit plus the gaskets starts to approach the cost of a new unit that solves everything at once, and it leaves you with an old window that opens by itself.

We set that comparison out rather than quoting for the kit because the kit is what was asked for.

Freeing a stiff mechanism first

An actuator sized for a window in good order will struggle with one that has stiffened, and it will report that as an obstruction.

So a retrofit onto a stiff unit starts with the unit: the hinges or pivots cleaned and lubricated as the manufacturer specifies, the gaskets checked and replaced if hardened, and the sash operated fully by hand to confirm it moves freely through its whole travel.

Skipping that produces a window that opens slowly, stops short and gets reported as a faulty motor within a year.

A tape measure stretched corner to corner across the diagonal of a timber rooflight kerb on a flat roof, checking it for square, no hands in frame
Mounting into something that will hold

Mounting into something that will hold

The forces and the mounting points are covered on the chain actuator page. What is specific to a retrofit is that you are fixing into a frame that has already had thirty years of weather.

Timber that has taken water at the sill, or an aluminium section corroded around an old fixing, will not hold a mounting under cyclic load however well the bracket fits. On a coastal unit that is a real possibility rather than a remote one.

It is checked before the kit is bought rather than discovered while fitting it.

Adding a sensor at the same time

A retrofit is the moment to fit a rain sensor, because the controller is going in anyway.

On this coast a sensor on a powered unit is close to essential, and adding one later means another visit and another commissioning. Where the controller supports it, it costs very little at the same time.

How a sensor behaves in a Channel sea fret is worth reading before deciding the sensitivity, and it has its own page.

Blinds and the retrofit

Where a blind is going to be wanted as well, doing both at once is neater and cheaper than either separately.

Both attach to the sash and the frame, both are ordered against the same size code, and both are fitted from inside with the same access arrangement. On a high window that access is most of the job.

It is worth asking the question at the same time rather than a year later.

Retrofitting to several windows at once

Where a room or a house has more than one window of the same generation, doing them together is considerably better value.

Many controllers will drive more than one actuator, so a second and third unit can frequently share the controller, the supply and the sensor rather than each needing their own. On a solar retrofit each unit is independent, and the access arrangement is still shared.

It also means the room ends up consistent: one control operating everything, rather than one powered window and two that still need a pole, which is an arrangement nobody is happy with.

A large electrically operated flat rooflight standing open on its chain actuator above a flat roof, the opening sash raised clear of the kerb, grey overcast sky above
Older units and the parts question

Older units and the parts question

A retrofit frequently turns into a small service job, and that is a good outcome rather than a bad one.

Once somebody is at the window with it open, the gaskets, the handle, the cleaning catch and the hinges are all accessible and all are replaceable parts ordered against the same code. A unit that has become stiff and draughty and is about to be motorised is a unit worth putting right at the same moment.

The cost of doing those parts while the access is already arranged is a fraction of doing them as a separate visit, and it is the difference between a motor on a tired window and a window that works properly and now opens itself.

Retrofitting a flat roof unit

Nearly all of the above concerns pitched roof windows. On a flat roof the position is different and generally worse.

Most flat rooflights are either fixed, or supplied as opening units with the actuator integral from the start. There is rarely a retrofit path from one to the other, because a fixed unit has no opening sash, no hinges and no seal designed to be compressed and released.

Converting a fixed flat rooflight to an opening one is a new unit rather than a kit, and it is honest to say so straight away.

Doing it as part of something else

Where a ceiling is coming down anyway, for a loft conversion, a rewire or a repair, the calculation changes completely.

At that moment a mains cable is minutes of work rather than a disruption, so the mains option comes back into play and with it a wider choice of controllers and accessories. It is also the moment to fit the insulation collar that the original installation probably lacks.

If any work of that kind is planned within a couple of years, waiting for it is usually the better call and we will say so.

What to send us before we visit

  1. A photograph of the data plate, in focus, with the whole label in frame.
  2. The window fully open from inside, showing how it opens.
  3. The handle, the catch and any ventilation flap.
  4. The frame at the bottom of the sash, which is where decay starts.
  5. The room, so we can see how high the window is and what is under it.

Five photographs, none needing a ladder, and between them they usually settle whether a retrofit is possible before anybody drives anywhere.

What we read on an opening unit

We read the data plate and check whether a kit exists for that model before discussing anything else, because that is the hard stop. We assess the frame, the mechanism and the gaskets rather than assuming, free a stiff unit before powering it, and specify solar on a finished room. Where the unit is old enough that a replacement is the better buy, we set out both and say which we would choose.

The motor is the easy part. Whether the window was built to take one is the whole question.

Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.

Get a fixed quote

Get a fixed quote

Tell us about the roof. We will tell you the price.

A survey costs you nothing and there is no obligation attached to it. We look at the roof build-up, the exposure and the opening, and give you one fixed figure, not an estimate that moves once work starts.

If your rooflight is leaking now, say so and we will prioritise the survey.

  • Fixed price, confirmed in writing
  • 10-year workmanship guarantee
  • Installed to current Building Regulations
  • Your roof is never left open overnight
Call Get a fixed quote