Around 15 degrees for most standard roof windows, with individual products stating their own figure and some going a little lower with a specified underlay detail. Conservation units are generally higher. Below the stated pitch the manufacturer will not warrant the unit, because water does not clear it reliably.
Why a minimum exists
Because a roof window relies on the slope to shed water past it.
On a steep roof water runs off quickly and the flashing only has to handle what passes. On a shallow one it moves slowly, sits longer at the head of the unit, and in wind is pushed back up the slope.
What happens below it
Not a leak on the first day, which is what makes it insidious.
A unit below its minimum pitch performs adequately in ordinary rain and fails in driven rain from the wrong direction, which is a fault that appears seasons later.
It is also outside warranty, which matters when it does.
How to measure it
With a level and a rule, or a pitch gauge, from inside the roof.
It is taken on the actual slope the window is going into rather than estimated from the street, because roofs are not always uniform and later additions run shallower.
Where shallow pitches turn up
Three places consistently.
Post-war and modern estate housing, which was built to shallower pitches than earlier stock. Rear additions and outshots on older cottages. And garage and outbuilding roofs.
The first is on the Hangleton page, where it is the dominant constraint.
Conservation units and pitch
Generally a higher minimum than a standard roof window.
A flush unit sitting low in the covering has less help from gravity, so the stated minimum is higher, and it rules the product out on a good number of shallow rear additions.
Which is worth knowing before an application is made on a slope that cannot take one.

What to do on a shallower roof
Three options, in order of preference.
A different slope on the same building where the pitch is adequate. A kerb mounted unit designed for low pitch. Or a product specifically made for shallow pitches, where one exists in the range.
Kerb mounted units
The usual answer, and it changes the appearance.
A unit on an upstand sheds water by height rather than by slope, in the way a flat roof unit does, and it can be used on a pitch below a roof window’s minimum.
It stands proud, which matters on a visible slope and rarely on a rear addition.
The projection consequence
Worth checking, because it can change the planning position.
A kerb adds height above the plane of the roof, and a unit that would have been permitted development flush may exceed the projection limit on an upstand.
The measurement is on what is the 150mm rule.
Underlay details for low pitch
Some manufacturers allow a lower pitch with a specified detail.
That generally means a particular underlay arrangement carrying water away below the covering, described in the installation instructions.
It is followed exactly rather than approximated, because the warranty depends on it.
Maximum pitch
It exists and is rarely a constraint.
Very steep slopes, and mansard faces in particular, can exceed a product’s maximum, at which point a vertical window or a different product is the answer.
What the covering adds
A second minimum, and it is easy to forget.
Every roof covering has its own minimum pitch below which it should not be laid, and it is frequently higher than the window’s.
A window within its range on a covering outside its own is still a roof that will leak.

Checking before ordering
Three numbers rather than one.
The measured pitch of the actual slope, the window’s stated minimum, and the covering’s minimum. All three have to work together.
Why it is measured rather than assumed
Because roofs vary and the eye is unreliable.
A shallow roof looks steeper from the ground than it is, and the difference between 14 and 17 degrees is invisible at a distance and decisive at a survey.
What we will not do
Fit a unit below its stated minimum pitch.
It is outside warranty, it is a fault waiting to happen, and it is the kind of shortcut that produces the leaks this trade is blamed for.
Why manufacturers state it
Because it is a tested limit rather than a cautious guess.
Products are assessed for weathertightness under driven rain at stated pitches, and the minimum is the point below which that testing no longer supports the claim.
Which is why fitting below it voids the warranty: the manufacturer has no evidence the unit performs there.
What a shallow pitch does to the room
A design consequence worth knowing alongside the technical one.
A window in a shallow slope sits closer to horizontal, so it shows more sky and less view, and it is harder to see out of from a seated position.
On a loft bedroom where the outlook is the point, a shallow pitch limits what is achievable even where the unit is within range.
What we take on a pitched roof
We take the pitch with a level at survey, check it against both the unit and the covering, and specify a kerb mounted or low pitch product where the slope will not take a standard one.
The whole picture is on the roof window installation page.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.