Energy Efficient Rooflights

What is the limiting U-value for a replacement rooflight?

Under current guidance the limiting U-value for a replacement rooflight is 2.2 W/m2K. Every current double glazed product clears it comfortably, generally landing well below it, so it is a floor rather than a target. What matters more than the number is the basis on which a supplier declares it.

What a limiting value is

A worst acceptable performance rather than a required one.

The regulations set a maximum U-value that a replacement element must not exceed. Anything better is fine, and no credit accrues for beating it.

Which is why it is not a useful basis for choosing between two modern products.

Why rooflights and skylights are allowed more than windows

Because a rooflight is genuinely harder to make perform.

The limit for a replacement window is tighter. A rooflight faces the open sky, sits above the warmest air in a room, and has more frame relative to glass on a small unit.

The comparison is on does a rooflight lose more heat than a window.

The plane it is declared in

The detail that makes two quoted figures incomparable.

A rooflight U-value can be declared in the horizontal plane, as tested, or converted to the vertical plane for comparison with windows. The two are different numbers for the same product.

Guidance expects a particular basis, and a supplier quoting the flattering one is not comparing like with like.

Centre pane against whole unit

The other way a figure can mislead, and it is more common.

The centre pane value describes the glass alone. The whole unit value includes the frame, weighted by area, and is worse.

On a small rooflight with a lot of frame, the gap between the two is substantial.

What a good unit actually achieves

Comfortably below the limit, on the whole unit basis.

A current double glazed rooflight with a low emissivity coating, a gas fill and a warm edge spacer sits well under 2.2 as a whole unit.

Which is why compliance is rarely the difficult part of a replacement.

A rooflight sealed unit seen edge on against the light, the warm edge spacer bar and the low emissivity coating visible as a faint tint in the glass, clean and technical
What counts as a replacement

What counts as a replacement

Putting a new unit into an opening that already exists.

Where the opening is enlarged, or a new one is formed, it is new work assessed under different provisions rather than as a replacement.

The distinction is on do rooflights need to meet building regulations for heat loss.

Whether a replacement is notifiable

Generally not, and it still has to comply.

Putting a new unit into an existing opening is not normally notifiable work, which means nobody inspects it. The obligation to meet the standard is unchanged.

Which puts the responsibility on the specifier rather than on an inspector.

Historic buildings

Where the standard can be relaxed, and it is a genuine provision.

The guidance allows for reasonable provision where full compliance would unacceptably alter the character or appearance of a historic or traditionally constructed building.

It is how a single glazed conservation unit can be acceptable on a listed building, and it is agreed with building control rather than assumed.

The standards change

Worth stating, because a number learned once goes out of date.

Limiting values have tightened over successive revisions and will tighten again. What applies is the standard in force when the work is carried out.

We confirm the current position at survey rather than working from memory.

Devolved differences

A qualification worth noting. Building regulations differ between England, Wales, Scotland and Northern Ireland, and the limiting figures are not identical across them.

Everything here refers to the guidance applying in England, which is where we work.

What the number does not tell you

How the installation will actually perform, which is the more important question.

A unit meeting the limit, fitted with insulation stopping short of the frame and no continuity of the vapour control layer, loses heat around itself in a way no declared value captures.

That loss is frequently larger than the difference between a compliant unit and a good one.

A cutaway section of a triple glazed rooflight unit showing the two cavities, the warm edge spacers and the thickness of the laminated inner pane
What to ask for

What to ask for

The whole unit figure, the plane it is declared in, and confirmation that the product is made for overhead use.

Three questions, and a supplier who cannot answer them is quoting a marketing number.

Where the figure does matter

Two cases. A large glazed area, where the total loss is no longer trivial. And any situation where an assessor is doing a calculation for an extension, because the declared value goes into it directly.

Documentation

Worth keeping, even on a job that is not notifiable.

The unit’s declared performance and the specification are what a future owner’s surveyor will ask about, and they are far easier to file at the time than to reconstruct.

What a competent person scheme changes

Worth knowing, because it affects who certifies the work.

Where an installer is registered under a competent person scheme for the work being done, they can self certify compliance and notify the local authority, which removes a separate building control application.

The obligation to meet the standard is identical either way; what changes is the route the paperwork takes.

Whole house improvement

A provision worth knowing about on a larger project.

Where a substantial amount of work is being done at once, there are routes that assess the improvement across the dwelling rather than element by element.

On a single rooflight it does not arise. On a re-roof with several units and new insulation it can.

How we quote it on the glazing

We quote whole unit figures on the basis the guidance uses, specify well below the limit as a matter of course, and detail the insulation at the frame because that is where the real performance is decided.

What the number means is on what U-value should a rooflight have.

Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.

Get a fixed quote

Get a fixed quote

Tell us about the roof. We will tell you the price.

A survey costs you nothing and there is no obligation attached to it. We look at the roof build-up, the exposure and the opening, and give you one fixed figure, not an estimate that moves once work starts.

If your rooflight is leaking now, say so and we will prioritise the survey.

  • Fixed price, confirmed in writing
  • 10-year workmanship guarantee
  • Installed to current Building Regulations
  • Your roof is never left open overnight