Sun Tunnel Installation

Adding a light kit to a tunnel for after dark

A sun tunnel delivers daylight and nothing at night. A light kit puts a lamp inside the diffuser so the same fitting lights the room after dark, which in a windowless room is the difference between one circle in the ceiling and two.

What a light kit is

A lamp assembly mounted within the tunnel above the diffuser, so that when it is switched on the diffuser glows in exactly the way it does in daylight.

From the room it is invisible. There is one circular diffuser in the ceiling and it is lit by the sky during the day and by the lamp at night, and most people cannot tell which is which from below.

It is an accessory to the tunnel rather than a separate fitting, and it uses the opening that is already there.

Why it matters more than it sounds

Because of where sun tunnels go.

They serve internal rooms: bathrooms, hallways, landings, cloakrooms. Those rooms are used before dawn and after dark for a good part of the year, so a tunnel alone leaves them needing their conventional lighting anyway.

Which means without a light kit the ceiling has a diffuser and a light fitting, in a small space where both are visible and neither is centred properly because the other is in the way.

With one, the ceiling has a single tidy circle. In a small bathroom or a narrow hall that is a real gain.

The ceiling clutter argument

A small bathroom ceiling, with and without
Tunnel alone Tunnel with light kit
Openings in the ceiling Two, plus an extract One, plus an extract
Positions Neither ideally placed One, placed properly
Light source at night A separate fitting The diffuser
Wiring To the light fitting To the tunnel
Appearance Two objects One

Fit it at installation

The recommendation, and the reason is the cable rather than the lamp.

A light kit needs a supply at the tunnel, in the roof space. At the moment the tunnel is being installed, somebody is already up there with the run open and the ceiling opening formed, and running a cable to it is minutes of work.

Afterwards it means going back into the roof space, which is possible and is a separate visit with a separate access.

Which produces the same advice as on every powered rooflight: even where the light kit itself is not wanted now, running the cable while the ceiling is open costs almost nothing and turns a future decision into a simple one.

Retrofitting one

Entirely possible where there is roof space access.

The kit fits into the existing tunnel, generally from the roof space, and the supply is run to it. Where the loft is accessible and the tunnel is a current model with a kit available, it is a straightforward upgrade.

Where it is difficult is a shallow or inaccessible roof space, or an older tunnel with no compatible kit. The data plate or the manufacturer identifies whether one exists.

The roof dome of a sun tunnel installed on a tiled slope with its flashing dressed into the courses, seen from ladder height
Wiring and switching

Wiring and switching

The electrical side, and it is ordinary.

The kit is a light fitting in a ceiling, wired and switched like any other. It can go on the room’s existing lighting circuit and be operated by the room’s existing switch, which is generally what people want.

Where a room has other lighting as well, the kit can be switched separately, which in a hallway gives a low level option distinct from the main light.

The connection is electrical work and it is done by an electrician, and whether it is notifiable under Part P depends on what is being done and where.

Bathrooms and ratings

The situation where the specification matters, and it is worth naming.

Bathrooms are divided into zones for electrical purposes and a fitting in a given zone has to be suitable for it. A light kit in a bathroom ceiling is a light fitting in a bathroom, so the same requirements apply.

Which zone a ceiling position falls into depends on its distance from the bath or shower, and the electrician establishes it. What matters at specification is choosing a kit with an appropriate rating rather than a general purpose one.

What it looks like lit

Worth setting expectations, because it is not a downlight.

The diffuser glows evenly across its whole face, which gives a soft, spread light rather than a beam. In a small room that is pleasant and it is genuinely different from a spotlight.

What it is not is directional. Where somebody needs task light over a mirror or a worktop, the tunnel is the general light and a task fitting is still wanted.

How much light it gives

Enough for a small internal room, and it is worth checking against the room.

Light kits are specified in the usual way and the better ones give a genuinely adequate level for a bathroom, a hallway or a landing. In a larger space a single kit is a general light rather than the whole answer.

The useful question is what the room needs at night, and it is a different question from what the tunnel delivers by day. A room lit adequately by a generous tunnel in June may want more than a light kit gives in December.

Dimming

Available on some systems and worth asking about.

A dimmable kit in a bathroom or a landing gives a low level at night, which in a house where somebody crosses a landing in the small hours is genuinely useful.

Whether a particular kit dims, and what dimmer it needs, is a product question. Fitting a dimmer to a fitting not designed for one produces flicker and a shortened lamp life, so it is worth establishing rather than assuming.

Colour temperature

A choice that matters more here than in most fittings.

The diffuser is being lit by daylight for part of the day and by the lamp for the rest, through the same surface. A lamp with a very cool colour reads as different from the daylight; a warmer one reads as evening light, which is generally what a bathroom or a hallway wants after dark.

Most people prefer a warm colour for that reason, and it is worth choosing rather than accepting whatever is supplied.

The inside of a trussed rafter roof space, W shaped webs and punched metal plate joints clearly visible at the intersections, daylight from a gable vent
Lamp life and replacement

Lamp life and replacement

The practical question over the years, and it is worth asking before ordering.

Current kits use long life lamps, so replacement is infrequent. When it is needed, the question is how: whether the lamp is reachable from the room by removing the diffuser, or whether it means going into the roof space.

A kit serviceable from below is considerably better on a tunnel serving a room with a shallow or awkward loft above it. It is worth asking, because it is not obvious from a catalogue.

Heat in the tube

A minor consideration and worth mentioning. A lamp inside a sealed tube generates a little heat and current lamps generate very little. Kits are designed for the enclosure they sit in, which is why a manufacturer’s kit is specified rather than a lamp somebody fitted into a tunnel.

Improvising a light inside a sun tunnel is not a good idea for exactly that reason, and it also compromises the sealing that keeps the tube dry.

Sealing, which the kit must not break

The technical requirement that matters most. A sun tunnel is a sealed pipe, and the sealing is what keeps humid room air out of the tube and dust out of the reflective surface. A light kit is a component introduced into that pipe with a cable passing into it.

A manufacturer’s kit is designed to maintain the seal. A hole cut in a tube for a cable, with the lamp cable-tied inside, is not, and in a bathroom it is the beginning of a condensation problem.

Which is the strongest argument for a matched kit rather than an improvised one.

What it does not replace

Two things, so expectations are right. It does not replace task lighting where a room needs it. And it does not replace the extract in a bathroom, which is a separate requirement the tunnel does not touch either.

What it replaces is the general ceiling light, which in a small internal room is the fitting it was going to duplicate.

Emergency and escape lighting

Worth a note for completeness on shared buildings.

Where a sun tunnel serves a common stairwell or a shared circulation route in a block, any emergency lighting requirement is part of the building’s fire strategy and is not satisfied by a light kit.

That is a designed provision with its own standards, and it sits alongside rather than inside a daylight product. On a domestic installation it does not arise.

Marine grade stainless steel fixings and a coated aluminium frame section laid out on a roof membrane before installation, salt haze in the air
Whether to fit one at all

Whether to fit one at all

The honest test. Where the room is internal and will need lighting after dark anyway, and the ceiling is small enough that two fittings would be visibly crowded, yes. That describes most bathrooms, cloakrooms and landings.

Where the room already has good lighting well positioned, and the tunnel is being added purely for daylight, the kit is a tidiness improvement rather than a necessity, and the existing fitting is doing its job.

The cable, again

The point worth repeating because it is the one that costs nothing now and something later.

Even where the decision is no, run the cable and leave it. It is a few metres and ten minutes while somebody is in the roof space with the run open.

In five years, when the room has changed use or the household has changed its mind, the difference between having that cable and not is a morning in a loft.

Running costs

Modest, and worth a sentence because it comes up.

A light kit is one lamp of the sort any ceiling fitting would carry, so its running cost is whatever a single light in that room would be. It is not an addition to the household’s lighting; it is the replacement for a fitting that would have been there anyway.

What the tunnel itself saves, by lighting the room in daylight hours, generally exceeds it comfortably in a room that was previously lit artificially all day.

Sensors and automation

Available on some systems and worth considering in the right room.

A presence sensor on a hallway or a landing means the light comes on when somebody is there and off when they are not, which in a circulation space is exactly the behaviour wanted and is easy to forget to do manually.

A daylight sensor is less useful than it sounds, because the diffuser is already telling you how bright it is outside and people switch accordingly. The presence sensor is the one that earns its place.

What to ask before ordering

  1. Is a light kit available for this tunnel model and diameter?
  2. Is it rated for a bathroom, and to what zone?
  3. Is it dimmable, and with what dimmer?
  4. What colour temperature, and is there a choice?
  5. Is the lamp serviceable from the room, or from the roof space?
  6. Does fitting it maintain the seal of the tube?

What we raise on a sun tunnel

We raise the light kit question at survey on any internal room, because the ceiling is going to need a light either way and one opening is better than two. We run the cable while the roof space is open even where the kit is not being fitted now, specify a matched kit rather than an improvised lamp, and choose a warm colour so the diffuser reads consistently day and night.

One circle in the ceiling, lit by the sky in the day and a lamp at night. In a small internal room that is the tidiest answer there is.

Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.

Get a fixed quote

Get a fixed quote

Tell us about the roof. We will tell you the price.

A survey costs you nothing and there is no obligation attached to it. We look at the roof build-up, the exposure and the opening, and give you one fixed figure, not an estimate that moves once work starts.

If your rooflight is leaking now, say so and we will prioritise the survey.

  • Fixed price, confirmed in writing
  • 10-year workmanship guarantee
  • Installed to current Building Regulations
  • Your roof is never left open overnight
Call Get a fixed quote