Energy Efficient Rooflights

What is a warm edge spacer?

The spacer is the bar running around the perimeter of a sealed unit, holding the two panes apart and sealing the cavity. A warm edge spacer is made of a low conductivity material, stainless steel or a composite, rather than the aluminium traditionally used. It reduces heat loss at the edge of the glass and raises the temperature there.

What the spacer does

Three jobs at once, which is why it matters more than it looks.

It holds the panes at a set distance, it seals the cavity so the gas fill stays in and moisture stays out, and it carries a desiccant that absorbs any moisture that does get in.

A sealed unit fails when the spacer’s seal fails, so it is also the component that decides service life.

Why aluminium was a problem

Because it conducts heat extremely well, which is exactly wrong here.

An aluminium spacer is a continuous metal bridge from the inner pane to the outer one, running the whole perimeter of the unit, carrying heat straight across the cavity the glazing exists to create.

Whatever the centre of the glass achieves, the edge undoes some of it.

What warm edge means

A spacer made of something that conducts far less.

Stainless steel, which conducts much less than aluminium, or a composite or polymer with a thin barrier layer. Both do the same structural job with a fraction of the heat transfer.

What it improves

Two things, and the second is what people actually notice.

It improves the whole unit U-value modestly, by reducing the loss at the perimeter.

And it raises the surface temperature at the edge of the glass, which is where condensation forms first.

Why the edge matters most on a rooflight

Because these are small units with a lot of perimeter.

A rooflight is a modest opening, so the ratio of edge to glass area is high, and the edge effect is a larger share of the whole than it would be on a patio door.

Which is why warm edge is worth more on a rooflight than on a large window.

A warm edge spacer bar at the corner of a sealed glazing unit seen very close, the desiccant perforations and the depth of the seal legible
The condensation benefit

The condensation benefit

The practical reason to specify it. Condensation begins at the coldest point, which on a sealed unit is the edge of the glass just inside the frame. A warmer edge means it forms later, at a lower temperature or a higher humidity.

In a kitchen or a bathroom under a rooflight that is a real gain.

What it does not fix

The frame, which is generally colder than the glass edge anyway.

A warm edge spacer improves the glazing perimeter. It does nothing about a frame with a poor thermal break, and nothing at all about insulation stopping short at a reveal.

Those are larger effects on most installations.

How to tell what a unit has

By looking at the edge, and it is visible.

An aluminium spacer is bright silver metal. A warm edge one is generally black, grey or a dull metallic, and it is visible through the glass around the perimeter of the pane.

On a new unit it is on the specification; on an existing one it is a look.

Whether it is standard now

On good units yes, and it is worth confirming rather than assuming.

Most reputable manufacturers use warm edge as standard, because the whole unit figures they quote depend on it. Cheaper units and some older stock still use aluminium.

Whether it can be changed

Only by replacing the sealed unit, because it is inside it.

Where a frame is sound, replacing the glazing alone is frequently possible and gives a modern spacer along with modern coatings.

A vapour control membrane carried up the inside face of a rooflight kerb and taped to the frame, the tape line clearly visible, construction in progress
Appearance

Appearance

A small consideration on a rooflight seen from below.

The spacer is visible as a line around the edge of the glass, and a black one reads as part of the frame while a bright aluminium one reads as a separate silver line.

On a dark framed conservation unit, a black spacer looks considerably better.

Service life

Where the spacer’s other job matters. Sealed units fail when the perimeter seal admits moisture, which the desiccant then absorbs until it is saturated and misting begins.

A well made spacer with good sealing is what makes that take decades rather than years.

On a rooflight specifically

A harder duty than on a window, and it is worth knowing.

A rooflight sits in a horizontal or near horizontal plane, is exposed to more direct sun and greater temperature swings, and water sits on it rather than running off quickly.

Which is why rooflight sealed units are built for that duty and why a unit made for a window is not a substitute.

What to ask a supplier

Two questions. Whether the spacer is a warm edge type, and what the whole unit U-value is with it. A quoted centre pane figure hides the spacer’s contribution entirely.

The distinction is on what U-value should a rooflight have.

What it costs

Little or nothing as a specification choice, because on most current products it is already there.

Where it is offered as an upgrade, it is a modest amount for a real improvement at the point where condensation actually starts.

What we specify on the glazing

We specify warm edge as standard and a black spacer on dark framed units, and we quote whole unit figures so the perimeter is included rather than hidden.

The whole picture is on the energy efficient rooflights page.

Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.

Get a fixed quote

Get a fixed quote

Tell us about the roof. We will tell you the price.

A survey costs you nothing and there is no obligation attached to it. We look at the roof build-up, the exposure and the opening, and give you one fixed figure, not an estimate that moves once work starts.

If your rooflight is leaking now, say so and we will prioritise the survey.

  • Fixed price, confirmed in writing
  • 10-year workmanship guarantee
  • Installed to current Building Regulations
  • Your roof is never left open overnight
Call Get a fixed quote