Triple glazing overhead, and the weight it adds to the frame
Triple glazing is assumed to be an upgrade in the way that more is better. Overhead it brings costs that do not arise in a wall, and there are situations where it is the right answer and rather more where it is not.
What the third pane buys
A second cavity, and a second low emissivity coated surface. Both reduce the heat transfer through the middle of the unit, and the improvement in the centre pane U-value is genuine.
The improvement in the whole unit figure is smaller, because the extra pane does nothing for the edge or the frame, and on a rooflight the perimeter is a substantial proportion of the product. What is measured and what is delivered are two different things, which the whole unit page covers.
The weight
This is the constraint that matters overhead and it is the one nobody raises.
Three panes rather than two, plus a second spacer and a second gas fill, is roughly half as much glass again. On a small unit that is manageable. On a large one it is a considerable additional dead load, sitting horizontally over a room, carried by a frame and then by a kerb and then by the trimmed opening beneath it.
In a wall, glass weight goes straight down through the frame into the cill. Overhead, it is a bending load on everything under it, for the life of the building.
What has to take it
| Component | What changes | Consequence |
|---|---|---|
| The frame | Carries more, deflects more | May need a deeper section, or a size limit |
| The opening mechanism | More to push and pull | A higher rated actuator, or no opening option |
| The kerb | More load, continuously | Bearing on all four sides matters more |
| The trimmers | More permanent load | Deflection limits get closer |
| Handling on site | Heavier to lift and carry | May decide the access arrangement |
Maximum sizes get smaller
Manufacturers publish maximum sizes, and the maximum for a triple glazed unit is generally smaller than for the same product double glazed.
Which produces a decision people do not expect: the choice can be between a larger double glazed rooflight and a smaller triple glazed one. In a room where daylight is the point, that is frequently an easy call in favour of the double.
It is worth asking for both figures rather than assuming the size you want is available either way.

Getting it onto the roof
A triple glazed unit is heavier to handle, and handling is a real constraint on a good proportion of the houses here.
On a terraced house with no side access, everything goes through the front door and up the stairs. A unit two people could manage double glazed may need more people, or a lift, triple glazed. That is a cost and sometimes a road closure.
Establishing it at survey rather than on delivery day is the difference between a plan and a problem.
It is not quieter in rain
The most common reason people ask for triple glazing on a rooflight is noise, and it is the reason it is least likely to deliver.
Three panes with two narrow cavities can perform worse acoustically than two panes with one wider cavity, because narrow cavities couple the panes together rather than isolating them. The panes resonate more like a single stiff assembly.
What actually reduces rain noise is mass, damping and asymmetry: a laminated inner pane, an acoustic interlayer, and panes of different thicknesses. All three are available in a double glazed unit and all three are cheaper than a third pane.
Rain noise and what genuinely reduces it has its own page, and the short answer is that the money is better spent on laminate.
External noise, which is a different problem
Rain on the glass and traffic outside are two different acoustic problems and they have partly different answers.
For external noise, mass and asymmetry help again, and an acoustic interlayer helps a great deal. A third pane contributes, and less than the laminate does for the money. The acoustic laminates page covers the external case.
In neither case is triple glazing the efficient way to buy quiet.
Where it is genuinely worth it
Three situations, and they are all about heat rather than sound.
- A large north facing rooflight over a room that is hard to heat. No solar gain to offset the loss, a big cold surface overhead, and the U-value doing real work all winter.
- A very high performance house, where the fabric standard elsewhere is such that a double glazed rooflight becomes the weak point in the envelope.
- A room with a very large glazed area, where the total heat loss through the roof glazing is a significant proportion of the room’s demand.
Outside those, a good double glazed unit with a warm edge spacer, an argon fill and a properly insulated kerb will outperform a triple glazed unit on a poor kerb, for less money.
The kerb argument, again
It is worth repeating in this context because the arithmetic is stark.
The difference between a good double glazed rooflight and a triple glazed one is modest. The difference between an insulated kerb and an uninsulated one is a thermal bridge running the entire perimeter of the opening, and it loses considerably more than the third pane saves.
Specifying triple glazing onto an uninsulated kerb is paying for performance the installation then gives away. If the budget only stretches one way, it goes into the detail.

Solar gain and the third pane
A third pane reduces the g-value as well as the U-value, because there is more glass and more coating for the energy to pass.
On a south facing rooflight that is helpful and it is not an efficient way to buy solar control, because it costs light transmission at the same time and a solar control coating does the job better and lighter.
On a north facing rooflight the reduced light transmission is a straightforward loss, which is the same argument the north light page makes about solar control.
Condensation on the outside
A better insulated unit shows external dew more readily, and triple glazing shows it more than double.
The mechanism is that a well insulated unit leaks so little heat that its outer pane drops below the dew point of the outside air on clear still nights. The glass reads misty first thing and clears within an hour or two of sun or breeze.
It is evidence the unit is working rather than a fault. It is worth knowing before rather than after, because on a triple glazed rooflight it happens on more mornings a year and people report it.
What ages in a triple unit
Two sealed cavities means two edge seals and two gas fills, and both are things that can fail.
The probability of a seal failure over decades is not doubled in any simple way, and there is more to go wrong than in a double glazed unit. The unit is also heavier, so the edge seals carry more load, particularly on a horizontal installation where the glass is sagging very slightly under its own weight for its entire life.
None of that is an argument against triple glazing. It is an argument for weighing it rather than assuming more is better.
Frame depth and sightlines
A thicker unit needs a deeper rebate, which means a chunkier frame section for the same structural performance.
On a rooflight where the proportion of frame to glass is already high, particularly a small unit or a lantern with several bars, that is visible from inside. The slim sightline that makes a lantern read as open is harder to achieve with a thicker unit in it.
Where appearance matters, that trade is worth seeing before ordering rather than describing.

Opening units
An opening triple glazed rooflight has all of the above plus a mechanism lifting the extra weight.
That means a higher rated actuator, higher loads on the hinges and stays, and on some products no opening option at all above a certain size. On an exposed site where wind is already loading the mechanism, it compounds.
Where an opening unit is wanted and triple glazing is being considered, check the actuator rating and the maximum opening size together rather than in sequence.
Vacuum glazing, the other route
There is a third option that gets asked about and is worth knowing exists, because it addresses the weight problem directly.
Vacuum insulated glazing puts two panes very close together with the air evacuated between them, supported by an array of tiny spacers. With no gas in the cavity there is no conduction or convection across it, so a very thin unit can reach a U-value comparable to triple glazing at a fraction of the thickness and a good deal less weight.
It is considerably more expensive, availability in rooflight products is limited, and the support pillars are faintly visible on close inspection. Where it is genuinely useful is a conservation setting, where the slim overall thickness lets a modern performance unit sit in a frame designed for single glazing. It is worth asking about on a listed roof and it is not a mainstream domestic answer yet.
Argon, krypton and the cavity width
A detail specific to triple glazing and worth knowing before comparing quotations.
A triple glazed unit has two cavities to fit within an overall thickness, so each cavity is narrower than the single cavity of a double glazed unit of similar depth. Argon performs best at a particular cavity width, and narrower than that its advantage falls away.
Krypton is denser again and performs better in a narrow cavity, which is why it appears in slim triple glazed units. It is considerably more expensive, and a triple glazed unit with narrow argon filled cavities may not outperform a well made double glazed one by as much as the pane count suggests.
The honest comparison
For most domestic rooflights on the roofs we work on, the order of value is clear and it is not the order people expect.
- Replace an old or failed unit. The largest single gain by a wide margin.
- Insulate the kerb or the reveal properly, and seal the vapour control layer.
- Specify a warm edge spacer and an argon fill, which are close to free.
- Get the solar control right for the orientation.
- Add a laminated inner pane, which you are having anyway for safety.
- Then, if the case is one of the three above, consider triple glazing.
What we want to know on the glazing
We ask why triple glazing is wanted before quoting for it, because if the answer is rain noise it is the wrong product and we would rather say so. Where the case is a large north facing unit or a high performance house we specify it and check the frame, the maximum size, the handling route and the actuator rating together. Otherwise we put the money into the kerb detail and the glass specification, and say why.
Overhead, a third pane is weight as well as performance. It is worth having where it is doing something, and it is not an upgrade by default.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.