Double, on almost every product in almost every range. Triple glazing is available as an option on many units and is the exception rather than the norm on a domestic roof. Single glazing survives only in specific conservation situations. If a quote does not say, it is double.
What comes as standard
A double glazed sealed unit with a low emissivity coating, an inert gas fill and a warm edge spacer.
That combination is the baseline across current products, and it comfortably clears the limiting standard for a replacement rooflight.
What each component does is on what U-value should a rooflight have.
Why double became the standard
Because it delivers most of the available benefit for a fraction of the weight and cost.
Going from single to double glazing is a transformation in performance. Going from double to triple is a smaller increment, and it brings weight, thickness and cost with it.
Where triple is offered
On many mainstream ranges as an upgrade, and not on every profile.
Slim framed and conservation units frequently cannot accept a triple glazed unit at all, because the frame depth was drawn around a double glazed one.
So on some products the option simply does not exist, and it is worth establishing before deliberating.
Whether triple is worth it
Usually not on a domestic rooflight, and there are cases where it is.
The full argument, including weight, thickness, light loss and where the money does more, is on is triple glazing worth it in a rooflight.
Single glazing
Effectively obsolete, with one genuine exception.
On some listed buildings a conservation officer may prefer the reduced sight lines or the reflection characteristics of a single sheet, and the regulations allow for reasonable provision on historic buildings.
It is uncommon, it is agreed with the officer and building control, and it is never chosen on price.

What an old rooflight probably is
Worth checking on a replacement, because it sets the improvement.
A plastic dome from the seventies or eighties is frequently single skin. Early double glazed units exist and perform far below a current one, and an original Victorian cast iron light is single glazed.
Replacing any of those with a current unit is a substantial gain rather than a marginal one.
Twin wall and multiwall polycarbonate
A category people encounter and it is not glazing in this sense.
Multiwall polycarbonate sheets have several layers and provide insulation, and they are not sealed glass units. They yellow, they craze, and they do not perform like glass.
They appear on older domes and on some cheap flat roof products, and replacing one with a glazed unit is a considerable improvement.
Cavity width
A specification detail that matters more than the pane count on some units.
There is an optimal cavity for a given gas fill: too narrow and conduction dominates, too wide and convection currents form within the cavity.
Which is why a slim unit with a narrow cavity may use krypton, and why a wider cavity is not automatically better.
Asymmetric units
Where the two panes differ in thickness, and it is worth asking for.
Two panes of different thickness perform noticeably better acoustically than two identical ones, because they do not resonate at the same frequency.
On a property near a road that is a more useful upgrade than a third pane.
Laminated panes
A separate specification from the pane count, and it belongs on overhead glazing.
A laminated inner pane holds together if it breaks, so a failure does not drop glass into the room below. It also improves acoustic performance and cuts ultraviolet.
It is the sensible specification on any rooflight above a room somebody uses.
Toughened panes
Frequently the outer pane, and for a different reason.
Toughening resists thermal stress and impact, both of which a roof gets more of than a wall. Solar control panes in particular are frequently toughened as standard.

What the regulations require
A U-value limit rather than a number of panes.
Nothing in the regulations specifies double or triple glazing. What is required is a limiting thermal performance, which good double glazing meets comfortably.
The detail is on do rooflights need to meet building regulations for heat loss.
On a conservation unit
Double as standard, and the appearance is unaffected.
The historic look is in the frame, the profile and the bar. The glass behind it is modern, and the detail is on are conservation rooflights double glazed.
On a lantern
Double throughout, and the specification varies by pane position.
A lantern has several panes at different angles, and it is reasonable for the ones taking the most sun to carry a stronger solar control specification than the others.
It is rarely offered and it is worth asking about.
What to check on a quote
Four things, and none is the pane count.
The whole unit U-value and its basis, whether the inner pane is laminated, whether there is a warm edge spacer, and whether the glass is specified by aspect.
Obscured and patterned glass
Available in either configuration and worth knowing about.
Where a slope is overlooked from higher ground and the room below is a bathroom, an obscured inner pane solves a privacy problem no positioning can.
It costs little and it has to be specified at order, because the obscuring is in the glass rather than applied to it.
What we specify as standard on the glazing
We specify double glazed units with a laminated inner pane and a warm edge spacer as standard, and triple only where the glazed area is large or a room is being built to a high fabric standard.
The whole picture is on the energy efficient rooflights page.
Thinking about this job? We survey across Worthing, West Sussex and the South Downs and give you a fixed price before any work starts, with a 10-year workmanship guarantee.